Cross-Laminated Timber Fire Testing Sees Promising Results

The International Code Council Ad-hoc Committee on Tall Wood Buildings provided five fire scenarios that were tested in each of the two one-bedroom apartments constructed using mass timber in a multi-story apartment building. The test scenarios included various arrangements of exposed and unexposed cross-laminated timber (CLT) with open doors between living and sleeping areas while the effectiveness of automatic sprinkler systems was simultaneously evaluated.

Test 1: a mass timber structure fully protected with gypsum wall board was subjected to a large furnishings and contents fire. The test was terminated after three hours without significant charring on the protected wood surfaces of the structure.

Test 2: approximately 30 percent of the CLT ceiling area in the living room and bedroom were left exposed. The test was terminated after four hours, providing additional time to determine if there would be any significant fire contribution from the exposed CLT. Notably, once the furnishings and contents had been consumed by the fire, the exposed CLT essentially self-extinguished due to the formation of char that protected the underlying wood.

Test 3: parallel CLT walls were left exposed, one in the living room and one in the bedroom. Similar to Test 2, once the apartment furnishings and contents had been consumed by the fire, during which a protective surface of char formed on the CLT, the mass timber surfaces essentially self-extinguished.

Test 4 and 5: examined the effects of sprinkler protection. For both tests, all mass timber surfaces in the living room and bedroom were left exposed. Test 4 demonstrated that under normal operating conditions, a single sprinkler easily contained the fire. For Test 5, the fire was allowed to grow in the compartment for 23 minutes before water was supplied to the sprinklers which quickly controlled the fire.

From Woodworking Network: https://www.woodworkingnetwork.com/architectural-products/cross-laminated-timber-fire-testing-sees-promising-results?ss=news,news,woodworking_industry_news,news,almanac_market_data,news,canadian_news

U.S. Forest Service: Build Better, Stronger, Faster With CLT

The U.S. Forest Service is working to build markets for innovative forest products. One of these products, cross-laminated timber, also known as CLT, offers an opportunity for raising tall buildings with wood, opening up a completely new market for wood products.

And there’s tremendous opportunity to increase the market share for wood-based construction. Because of its high strength, CLT is an advantageous alternative to traditional building materials such as concrete, masonry, and steel. Because CLT panels resist compression, they are well-suited for building multistory structures, especially mid-rise buildings. Made from layers of dried lumber boards, stacked in alternating direction at 90-degree angles, glued and pressed to form solid panels, CLT has exceptional strength and stability and can be used as walls, roofs, and floors.

Additionally, CLT is highly resilient to fire, earthquakes, and even explosions. In fact in a recent series of live blast tests, CLT passed with flying colors. An examination of the results showed that the CLT structures suffered less degradation than expected and might outlast concrete and steel.

In terms of fire, CLT is like using a large log to start a campfire—it doesn’t ignite easily. And when it does burn, a char layer forms on the outside, protecting the inside and allowing the wood panel to maintain its structural integrity during fire scenarios.

Researchers have conducted extensive seismic testing on CLT and found that the panels perform exceptionally well in multi-story applications. When a seven-story CLT building was tested on the world’s largest shake table in Japan, it survived 14 consecutive earthquake simulations with almost no damage.

From the USDA: https://www.usda.gov/media/blog/2017/04/04/build-better-stronger-faster-clt